Estudo in vitro da quantidade do uso de pontas de ultrassom na eficiência da remoção de retentores metálicos
Carregando...
Data
Título da Revista
ISSN da Revista
Título de Volume
Editor
Universidade Federal do Amazonas
Resumo
The present study evaluated in vitro the influence of the amount of use of ultrasound tips on
the efficiency of removal of metallic retainers. Fifty endodontically treated upper canines
received fused metal retainers cemented with zinc phosphate cement. The specimens were
randomly randomized into 5 groups (n = 10), according to the removal protocol to which they
were submitted: G I (control) - Ultrasonic vibration using Remo C NOVA tip; G II-
Ultrasonic vibration using Remo C tip used 3 times; G III- Ultrasonic vibration using Remo C
tip used 5 times; G IV- Ultrasonic vibration using Remo C tip used 7 times; G V- Ultrasonic
vibration using Remo C tip used 9 times. The vibration protocol was 15 seconds on each face
(buccal, palatal, mesial and distal) totaling 1 minute, being the ultrasound Jetsonic Duo,
chosen for use under refrigeration. All specimens were subjected to tensile testing on the
Universal Testing Machine at a tensile speed of 1 mm / min until complete removal of the
root wall retainer. The maximum tensile force required for intrarradicular retainer removal
was recorded in Newtons. The recorded values were submitted to statistical analysis using the
Bioestat 5.0 program and normality tests and parametric and non-parametric tests were
performed with a 5% significance level. Normal values were found (Shapiro Wilk) and
ANOVA variance test was applied, with statistical difference (p.0051) P <0.05. TUKEY test
was performed and it was verified that groups 1 and 2 had the lowest means of traction force
(1-103N; 2- 104N) when using Nova tip and used 3x and the highest average 190N when used
9X tip (group 5). A statistical difference was found between groups 1 and 5 (p <0.05) and
groups 2 and 5 (p <0.05), with no difference found in the other groups tested. The study
highlights the importance of renewing the ultrasound tips to optimize ultrasonic efficiency. A
new tip is used up to 7 times maximum.