Utilização da cirurgia guiada na instalação de mini-implantes ortodônticos: aplicação de um protocolo para a prática clínica
Carregando...
Data
Autores
Título da Revista
ISSN da Revista
Título de Volume
Editor
Universidade Federal do Amazonas
Resumo
The usage of cone beam computed tomography associated with CAD/CAM
technology produce a reliable prototyped surgical guide and it's increasing the
accuracy in positioning the metallic screw, reducing problems of lesion to periodontal
ligaments and root surfaces. JUSTIFICATION: As in implantology, that the guided
surgery helped reduce the variations between the localization planned and executed
on installing metallic implants, the present study justifies itself by analyzing the usage
of this technique on orthodontics micro-implants surgery install and suggests a
protocol for daily use at clinical attendance. OBJECTIVES: The general aim is
evaluate the efficiency of a protocol developed with assistance of guided surgery for
orthodontic implant therapy; specifically, it aims to describe the use of virtual planning
and condensation silicon for the confection of the prototyped surgical guide molding
technique, evaluate the usage of the surgical guide concerning micro-implants
installation in posterior regions of maxilla and mandible, and produce a manual of the
protocol. METHODS: The patients were submitted to molding collect, acquisition of
cone beam computerized tomography for planning, installation surgery, and postoperation
tomography for the tridimensional evaluation of the metallic screws sites,
wtih a reckoning of angulation deviation and the localization. RESULTS: A total of 41
micro-implants were installed in 16 patients, with a average time of the surgical phase
was 2 minutes. Pain absence occurred in 81% of installations according to Visual
Analog Scale of Pain (VAS). Emplacement of micro-implants by the labial surface
medium deviation was 2,0 ± 0,8 mm on the head (D1), 1,9 ± 0,9 mm central (D2), 1,9
± 1,0 mm (D3) and 3,2°± 1,4 of long axis angulation (A1). Variations were higher by
the lingual surface (2,8 ± 1,6 mm, 3,1 ± 2 mm, 3,5 ± 2,3 mm e 4,4°± 2,3, respectively)
and distal surface of inferior molars 4,7 ± 3,3 mm, 4,8 ± 3,1 mm, 4,8 ± 2,9 mm, 4,5°
± 1,6, respectively). CONCLUSION: The offered protocol was efficient and of easy
execution, presenting itself as a viable and safe option for daily clinic.
Descrição
Palavras-chave
Citação
COSTA, Davi Mendes. Utilização da cirurgia guiada na instalação de mini-implantes ortodônticos: aplicação de um protocolo para a prática clínica. 2017. 117 f. Dissertação (Mestrado em Cirurgia) - Universidade Federal do Amazonas, Manaus, 2017.
Coleções
Avaliação
Revisão
Suplementado Por
Referenciado Por
Licença Creative Commons
Exceto quando indicado de outra forma, a licença deste item é descrita como Acesso Aberto

